Standard
walk-ins have applications in non-laboratory applications.
Walk-ins are available in standard size, with increments
of 11 ½” in length and width. Both coolers
and freezers are available, as well as multi-compartment
configurations.
All walk-ins are Factory mutual rated as Class One, and
carry UL ratings on the insulated wall construction.
FINISHES
Choose the finish which best suits your application.
Available finishes include galvanized, aluminum, stainless
steel and white.
DOORS
A variety of door options allows the user to have the
correct size opening to permit personnel and carts to
enter and egress the rooms.
|
|
click
on image to enlarge |
click
on image to enlarge |
REFRIGERATION SYSTEMS
Different building configurations and services dictate
the type of refrigeration systems that can be utilized.
Water-cooled
remote condensing units:
This system is commonly used in new construction,
where cold rooms are in construction configurations
that allow for cooling water to remove heat from the
condensing unit depicted here, a roof mounted water-cooling
tower recirculates the cooling water down to the condensing
unit. The unit may typically be mounted on top of
the cold room; however it may also be mounted in an
adjacent mechanical space. Refrigerant tubing is piped
to the cold room evaporator to complete the cooling
process. (Temperature control is still governed by
our exterior control panel).

Air-cooled
condensing unit removes heat by means of
ambient air surrounding the condensing unit, In these
applications, It is important to insure adequate free
air to properly cool the unit (contact factory for
further guidelines), Mounting the air cooled condensing
unit outdoors usually allows sufficient air flow,
(consult your local representative for more details
regarding proper mounting, supports etc,)
Roof
mounted air-cooled condensing units
allow for unrestricted cooling airflow to the unit,
Refrigeration piping is run in the shortest manner
possible to the cold room evaporator. This method
is limited in permissible distance in proportion to
the design temperature deviation tolerance that the
project requires. A specialized engineering design
will examine the proper line sizing and provisions
for refrigerant oil return to insure a well functioning
system, Consult your architect for roof loading factors.
Remote
air cooled, multi-circuited systems: Where
water-cooling systems are unavailable and interior
space discourages interior air cooling, remote air
cooled, multi-circuited systems are recommended, Numerous
cold rooms can be serviced by one or more roof-mounted
air-cooled condensers. These will be sized and engineered
to cool condensing units that are individually dedicated
to their respective cold rooms. Contact factory for
more details.
CONTROL
PANEL
A compact color display with a digital touch tone screen,
the control panel display monitors temperature/humidity
set points and actual performance. Multiple screens
permit authorized user (code protected) to easily adjust
set points alarm parameters, and other key data.

click on image to enlarge
There are NO Exposed conduit or wires and panel operates
at a safe low voltage. All unsightly conduit and high
voltage connections remain out of sight and away from
authorized personnel. Remote-top mount CPU driven, UL508A
Approved manufactured complete control panel.
Exclusive built-in electronic charting eliminates the
need to change paper and pens. Data can be downloaded
into user's PC based system and/or BMS systems.
Control Panel Brochure (pdf.)
|
|

©2004 Insulated-Structures™
|
|