Standard walk-ins have applications in non-laboratory applications. Walk-ins are available in standard size, with increments of 11 ½” in length and width. Both coolers and freezers are available, as well as multi-compartment configurations.

All walk-ins are Factory mutual rated as Class One, and carry UL ratings on the insulated wall construction.



FINISHES

Choose the finish which best suits your application. Available finishes include galvanized, aluminum, stainless steel and white.


DOORS

A variety of door options allows the user to have the correct size opening to permit personnel and carts to enter and egress the rooms.

click on image to enlarge
click on image to enlarge


REFRIGERATION SYSTEMS


Different building configurations and services dictate the type of refrigeration systems that can be utilized.
Water-cooled remote condensing units: This system is commonly used in new construction, where cold rooms are in construction configurations that allow for cooling water to remove heat from the condensing unit depicted here, a roof mounted water-cooling tower recirculates the cooling water down to the condensing unit. The unit may typically be mounted on top of the cold room; however it may also be mounted in an adjacent mechanical space. Refrigerant tubing is piped to the cold room evaporator to complete the cooling process. (Temperature control is still governed by our exterior control panel).

Air-cooled condensing unit removes heat by means of ambient air surrounding the condensing unit, In these applications, It is important to insure adequate free air to properly cool the unit (contact factory for further guidelines), Mounting the air cooled condensing unit outdoors usually allows sufficient air flow, (consult your local representative for more details regarding proper mounting, supports etc,)

Roof mounted air-cooled condensing units allow for unrestricted cooling airflow to the unit, Refrigeration piping is run in the shortest manner possible to the cold room evaporator. This method is limited in permissible distance in proportion to the design temperature deviation tolerance that the project requires. A specialized engineering design will examine the proper line sizing and provisions for refrigerant oil return to insure a well functioning system, Consult your architect for roof loading factors.


Remote air cooled, multi-circuited systems: Where water-cooling systems are unavailable and interior space discourages interior air cooling, remote air cooled, multi-circuited systems are recommended, Numerous cold rooms can be serviced by one or more roof-mounted air-cooled condensers. These will be sized and engineered to cool condensing units that are individually dedicated to their respective cold rooms. Contact factory for more details.

CONTROL PANEL

A compact color display with a digital touch tone screen, the control panel display monitors temperature/humidity set points and actual performance. Multiple screens permit authorized user (code protected) to easily adjust set points alarm parameters, and other key data.

click on image to enlarge
There are NO Exposed conduit or wires and panel operates at a safe low voltage. All unsightly conduit and high voltage connections remain out of sight and away from authorized personnel. Remote-top mount CPU driven, UL508A Approved manufactured complete control panel.

Exclusive built-in electronic charting eliminates the need to change paper and pens. Data can be downloaded into user's PC based system and/or BMS systems.

Control Panel Brochure (pdf.)